Select the value that is currently displayed in the three-digit display.
600 602 603 604 605 606 607 608 609 60c
610 611 612 614 615 616 617 618 619 61c
620 622 625 62c 63c 650 658 659 660 662
663 664 666 669 674 677 678 679 680 682
683 684 685 686 687 689 690 691 692 693
694 695 696 697 698 699 6c8
Explanation | Progress indicator. Starting network boot portion of /sbin/rc.boot. |
System Action | If an irrecoverable error occurs, the system halts and the operator panel displays a steady 600 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Configuring network parent devices. |
Explanation | Configuring physical network boot device. |
Explanation | Running /usr/sbin/ifconfig on logical network boot device |
Explanation | /usr/sbin/ifconfig failed. |
User Action | Report the problem to your software service organization. |
Explanation | Attempting to retrieve the client.info file with tftp. Note that a flashing 608 indicates multiple attempt(s) to retrieve the client_info file are occurring. |
Explanation | Progress indicator. A 1.4GB IDE Disk Drive is being identified or configured. |
System Action | The configuration method for the 1.4GB IDE Disk Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 60c value. |
User Action | If the system halts with the above action, try powering off attached SCSI devices. If this resolves the problem, check that each SCSI device has a unique SCSI id, and that cabling and termination are correct. Otherwise, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. |
Explanation | Accessing remote files; unconfiguring network boot device. |
Explanation | Configuring local paging devices. |
Explanation | Configuration of a local paging device failed. |
Explanation | Converting from diskless to dataless configuration. |
Explanation | Diskless to dataless configuration failed. |
Explanation | Configuring remote (NFS) paging devices. |
Explanation | Configuration of a remote (NFS) paging device failed. |
Explanation | Progress indicator. A 2.1GB IDE Disk Drive is being identified or configured. |
System Action | The configuration method for the 2.1GB IDE Disk Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 61c value. |
User Action | If the system halts with the above action, try powering off attached SCSI devices. If this resolves the problem, check that each SCSI device has a unique SCSI id, and that cabling and termination are correct. Otherwise, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. |
Explanation | Updating special device files and ODM in permanent filesystem with data from boot RAM filesystem. |
Explanation | Boot process configuring for operating system installation. |
Explanation | Progress indicator. A 3.0GB IDE Disk Drive is being identified or configured. |
System Action | The configuration method for the 3.0GB IDE Disk Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 62c value. |
User Action | If the system halts with the above action, try powering off attached SCSI devices. If this resolves the problem, check that each SCSI device has a unique SCSI id, and that cabling and termination are correct. Otherwise, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. |
Explanation | Progress indicator. A IDE CD-ROM Drive is being identified or configured. |
System Action | The configuration method for the IDE CD-ROM Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 63c value. |
User Action | If the system halts with the above action, try powering off attached SCSI devices. If this resolves the problem, check that each SCSI device has a unique SCSI id, and that cabling and termination are correct. Otherwise, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. |
Explanation | Progress indicator. Configuring a supported IBM SCSI disk drive. |
System Action | A supported SCSI disk drive is being configured. |
User Action | If the LED persists, then this most likely indicates the drive is failing to spin up and return the full VPD data. Under normal operations, this LED should only be seen once, just after the disk has been configured for the first time. If the drive is functioning correctly, AIX will use the LED value specified in the drive's VPD for subsequent reconfigurations. If repeated IPLs or reconfigurations continue to show this LED for a SCSI disk, there is a problem with the disk drive. |
Explanation | Progress indicator. PCI Fibre Channel Disk Subsystem Controller being identified or configured. |
System Action | The configuration method for the PCI Fibre Channel Disk Subsystem Controller is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 658 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. 2102 Fibre Channel Disk Subsystem Controller Drawer being identified or configured. |
System Action | The configuration method for the 2102 Fibre Channel Disk Subsystem Controller Drawer is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 659 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. 2102 Fibre Channel Disk Array being identified or configured. |
System Action | The configuration method for the 2102 Fibre Channel Disk Array is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 660 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. Integrated Ultra2 SCSI Controller being identified or configured. |
System Action | The configuration method for the Integrated Ultra2 SCSI Controller is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 662 value. Note: The Integrated Ultra2 SCSI Controller is located on the I/O board. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. ARTIC960 RxD PCI Adapter is being identified or configured. |
System Action | The configuration method for the ARTIC960 RxD PCI Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 663 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. 32x (MAX) SCSI-2 CD-ROM drive is being identified or configured. |
System Action | The configuration method for the 32x (MAX) SCSI-2 CD-ROM drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 664 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | The /usr filesystem has not been exported on the server with root permissions for the client. |
System Action | Phase 2 of a cfgmgr command failed during a sysback network boot. |
User Action | While in root, edit the /etc/exports file. By changing the line starting with /usr you provide root permission to all hosts performing a network boot. If access= appears on the /usr line, all hosts mentioned after the access= text are exported without root permission. For example, to export node4 with root permission you would need to do the following:
Change the line: /usr -ro, root=node1, node2:access=node3, node4to /usr -ro, root=node1, node2, node4:access=node3 exportfs -u exportfs -a exportfs (to verify the change took place) If the above procedure was followed and your system continues to hang on 666 reinstall your AIX operating system. Contact your local support representative when all the above has failed. |
Explanation | Progress indicator. PCI Gigabit Ethernet Adapter is being identified or configured. |
System Action | The configuration method for the PCI Gigabit Ethernet Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 669 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. ESCON Channel PCI Adapter is being identified or configured. |
System Action | The configuration method for the ESCON Channel PCI Adapter drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 674 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. PCI Fiber Channel Arbitrated Loop Adapter is being identified or configured. |
System Action | The configuration method for the PCI Fiber Channel Arbitrated Loop Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 677 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. 12GB 4mm Tape Drive is being identified or configured. |
System Action | The configuration method for the 12GB 4mm Tape Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 678 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. 4.5GB SCSI Disk Drive is being identified or configured. |
System Action | The configuration method for the 4.5GB SCSI Disk Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 679 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. Micro-Channel Adapter (MCA) Graphics Adapter is being identified or configured. |
System Action | The configuration method for the MCA Graphics Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 680 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. 12X - 20X SCSI CD-ROM Drive is being identified or configured. |
System Action | The configuration method for the 12X - 20X CD-ROM Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 682 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A 2105 Device is being identified or configured. |
System Action | The configuration method for the 2105 Device is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 683 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A 16-port RAN RS-422 for a 128-port adapter is being identified or configured. |
System Action | The configuration method for the 16-port RAN RS-422 for a 128-port adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 684 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A POWER GXT120P Graphics PCI Adapter is being identified or configured. |
System Action | The configuration method for the POWER GXT120P Graphics PCI Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 685 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. An 8-port PCI Asynchronous Adapter is being identified or congigured. |
System Action | The configuration method for the 8-port PCI Asynchronous Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 686 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A 128-port PCI Asynchronous Adapter is being identified or configured. |
System Action | The configuration method for the 128-port Asynchronous Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 687 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A 4.5GB Ultra-SCSI SE Disk Drive is being identified or configured. |
System Action | The configuration method for the 4.5GB Ultra-SCSI SE Disk Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 689 value. |
User Action | If the system halts with the above action, try powering off attached SCSI devices. If this resolves the problem, check that each SCSI device has a unique SCSI id, and that cabling and termination are correct. Otherwise, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. |
Explanation | Progress indicator. A 9.1GB Ultra-SCSI SE Disk Drive is being identified or configured. |
System Action | The configuration method for the 9.1GB Ultra-SCSI SE Disk Drive is being run. If an irrecoverable error occurs, the system will halts and the operator panel displays a steady 690 value. |
User Action | If the system halts with the above action, try powering off attached SCSI devices. If this resolves the problem, check that each SCSI device has a unique SCSI id, and that cabling and termination are correct. Otherwise, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. |
Explanation | Progress indicator. A Turboways 25Mbps ATM PCI Adapter is being identified or configured. |
System Action | The configuration method for the Turboways 25Mbps ATM PCI Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 691 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A DLT-7000 Drive is being identified or configured. |
System Action | The configuration method for the DLT-7000 Drive is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 692 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. An ISDN PCI Basic Rate Adapter is being identified or configured. |
System Action | The configuration method for the ISDN PCI Rate Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 693 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. An ISDN MCA Basic Rate Adapter is being identified or configured. |
System Action | The configuration method for the ISDN MCA Basic Rate Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 694 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. An X.25 PCI Coprocessor Adapter is being identified or configured. |
System Action | The configuration method for the X.25 PCI Coprocessor Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 695 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A Single Mode 8MB PCI ATM Adapter is being identified or configured. |
System Action | The configuration method for the Single Mode 8MB PCI ATM Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 696 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A Multi Mode 1MB PCI ATM Adapter is being identified or configured. |
System Action | The configuration method for the Multi Mode 1MB PCI ATM Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 697 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A UTP 1MB PCI ATM Adapter is being identified or configured. |
System Action | The configuration method for the UTP 1MB PCI ATM Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 698 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A 10/100Mbs PCI Ethernet Adapter is being identified or configured. |
System Action | The configuration method for the 10/100Mbs PCI Ethernet Adapter is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 699 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |
Explanation | Progress indicator. A display device driver is being identified or configured. |
System Action | The configuration method for a display device driver is being run. If an irrecoverable error occurs, the system halts and the operator panel displays a steady 6c8 value. |
User Action | If the system halts with this value, go to "Hardware Diagnostics" in in AIX Problem Solving Guide and Reference. If these procedures find a problem, report the problem to your hardware service organization. Otherwise, report the problem to your software service organization, and then stop. You have completed these procedures. |