[ Previous | Next | Contents | Glossary | Home | Search ]
AIX Version 4.3 Problem Solving Guide and Reference

X25 Error Identifiers for the Error Log

This category of identifiers contains the following error labels:

X25 ADAPT     X25 ALERT5    X25 ALERT7
X25 ALERT8    X25 ALERT9    X25 ALERT10
X25 ALERT11   X25 ALERT12   X25 ALERT13
X25 ALERT14   X25 ALERT15   X25 ALERT16
X25 ALERT17   X25 ALERT18   X25 ALERT19
X25 ALERT21   X25 ALERT22   X25 ALERT23
X25 ALERT24   X25 ALERT25   X25 ALERT26
X25 ALERT27   X25 ALERT28   X25 ALERT29
X25 ALERT30   X25 ALERT31   X25 ALERT32
X25 ALERT33   X25 ALERT34   X25 ALERT35
X25 ALERT36   X25 ALERT37   X25 ALERT38
X25 ALERT39   X25 CONFIG    X25 IPL
X25 UCODE

Go back to the categories of Error Identifiers.

X25 ADAPT

Error Description: ADAPTER ERROR

This error is logged by the X.25 device driver if the adapter card could not be found on the bus.

DETAIL DATA

Sense Data The sense data consists of failure data which is analyzed by the Diagnostic Programs.

X25 ALERT5

Error Description: X-5, MODEM FAILURE: DCD, DSR, CABLE

This error is logged by the X.25 device driver if the physical layer cannot be established to the modem. The signal lines DCD and DSR are not active.

Refer to Detail Data under X25 ADAPT.

X25 ALERT7

Error Description: X-7, MODEM FAILURE: ACU NOT RESPONDING

This error is logged by the X.25 device driver if the attached auto-call unit failed to establish a call.

Refer to Detail Data under X25 ADAPT.

X25 ALERT8

Error Description: X-8, X.21 NOT CONNECTED

This error is logged by the X.25 device driver when it fails to connect to an X.21 network.

Refer to Detail Data under X25 ADAPT.

X25 ALERT9

Error Description: X-9, FRAME TYPE W RECEIVED

This error is logged by the X.25 device driver if a W type FRMR frame is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT10

Error Description: X-10, FRAME TYPE X RECEIVED

This error is logged by the X.25 device driver if an X type FRMR frame is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT11

Error Description: X-11, FRAME TYPE Y RECEIVED

This error is logged by the X.25 device driver when a Y type FRMR frame is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT12

Error Description: X-12, FRAME TYPE Z RECEIVED

This error is logged by the X.25 device driver when a Z type FRMR frame is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT13

Error Description: X-13, FRAME TYPE W TRANSMITTED

This error is logged by the X.25 device driver when a W type FRMR frame is transmitted.

Refer to Detail Data under X25 ADAPT.

X25 ALERT14

Error Description: X-14, FRAME TYPE X TRANSMITTED

This error is logged by the X.25 device driver when an X type FRMR frame is transmitted.

Refer to Detail Data under X25 ADAPT.

X25 ALERT15

Error Description: X-15, FRAME TYPE Y TRANSMITTED

This error is logged by the X.25 device driver when a Y type FRMR frame is transmitted.

Refer to Detail Data under X25 ADAPT.

X25 ALERT16

Error Description: X-16, FRAME TYPE Z TRANSMITTED

This error is logged by the X.25 device driver when a Z type FRMR frame is transmitted.

Refer to Detail Data under X25 ADAPT.

X25 ALERT17

Error Description: X-17, FRAME RETRY N2 REACHED

This error is logged by the X.25 device driver when the frame level retry count (N2) is reached.

Refer to Detail Data under X25 ADAPT.

X25 ALERT18

Error Description: X-18, UNEXPECTED DISC RECEIVED

This error is logged by the X.25 device driver if a disconnect frame is received unexpectedly.

Refer to Detail Data under X25 ADAPT.

X25 ALERT19

Error Description: X-19, DM RXD DURING LINK ACTIVATION

This error is logged by the X.25 device driver when a DM frame was received after sending a SABM.

Refer to Detail Data under X25 ADAPT.

X25 ALERT21

Error Description: X-21, CLEAR INDICATION RECEIVED

This error is logged by the X.25 device driver if a clear indication packet with DCE-originated cause and diagnostics is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT22

Error Description: X-22, RESTART INDICATION RECEIVED

This error is logged by the X.25 device driver after a restart indication packet containing a DCE-originated cause and diagnostics was received by the DCE.

Refer to Detail Data under X25 ADAPT.

X25 ALERT23

Error Description: X-23, RESET REQUEST BY X.25 ADAPTER

This error is logged by the X.25 device driver if a reset request packet is sent automatically by the adapter.

Refer to Detail Data under X25 ADAPT.

X25 ALERT24

Error Description: X-24, CLEAR REQUEST BY X.25 ADAPTER

This error is logged by the X.25 device driver when the adapter code sent out a clear request with DCE-originated cause and diagnostics. The clear was not one requested by a higher layer.

Refer to Detail Data under X25 ADAPT.

X25 ALERT25

Error Description: X-25, RESTART REQUEST BY X.25 ADAPTER

This error is logged by the X.25 device driver when a restart request containing DCE-originated cause and diagnostics is transmitted.

Refer to Detail Data under X25 ADAPT.

X25 ALERT26

Error Description: X-26, TIMEOUT ON RESTART REQUEST, T20

This error is logged by the X.25 device driver if timer T20 expires before receipt of a restart confirmation packet.

Refer to Detail Data under X25 ADAPT.

X25 ALERT27

Error Description: X-27, TIMEOUT ON RESET REQUEST, T22

This error is logged by the X.25 device driver if timer T22 expires before receipt of a reset confirmation packet.

Refer to Detail Data under X25 ADAPT.

X25 ALERT28

Error Description: X-28, TIMEOUT ON CALL REQUEST, T21

This error is logged by the X.25 device driver if timer T21 expired before receipt of either a call connected or clear indication packet.

Refer to Detail Data under X25 ADAPT.

X25 ALERT29

Error Description: X-29, TIMEOUT ON CLEAR REQUEST, T23

This error is logged by the X.25 device driver if timer T23 expires before receipt of a clear confirmation packet.

Refer to Detail Data under X25 ADAPT.

X25 ALERT30

Error Description: X-30, DIAGNOSTIC PACKET RECEIVED

This error is logged by the X.25 device driver if a diagnostic packet is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT31

Error Description: X-31, RESET INDICATION PACKET RECEIVED

This error is logged by the X.25 device driver when a reset indication packet with DCE-originated cause and diagnostics is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT32

Error Description: X-32, (DCE) CLEAR INDICATION BY X.25 ADAPTER

This error is logged by the X.25 device driver when a clear indication containing DCE-generated cause and diagnostics is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT33

Error Description: X-33, (DCE) RESET INDICATION BY X.25 ADAPTER

This error is logged by the X.25 device driver if a reset indication packet containing a DCE-originated cause and diagnostics is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT34

Error Description: X-34, (DCE) RESTART INDICATION BY X.25 ADAPTER

This error is logged by the X.25 device driver after a restart indication packet containing a DCE-originated cause and diagnostics is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT35

Error Description: X-35, (DCE) RESTART REQUEST RECEIVED

This error is logged by the X.25 device driver when a restart request indication packet with DCE-originated cause and diagnostic codes is received.

Refer to Detail Data under X25 ADAPT.

X25 ALERT36

Error Description: X-36, (DCE) TIMEOUT ON RESTART INDICATION, T10

This error is logged by the X.25 device driver when timer T10 expired at the DCE before receipt of a restart confirmation packet.

Refer to Detail Data under X25 ADAPT.

X25 ALERT37

Error Description: X-37, (DCE) TIMEOUT ON RESET INDICATION, T12

This error is logged by the X.25 device driver if timer T12 expired before receipt of a reset confirmation packet.

Refer to Detail Data under X25 ADAPT.

X25 ALERT38

Error Description: X-38, (DCE) TIMEOUT ON CALL INDICATION, T11

This error is logged by the X.25 device driver if timer T11 expired before receipt of a call accept or clear request packet.

Refer to Detail Data under X25 ADAPT.

X25 ALERT39

Error Description: X-39, (DCE) TIMEOUT ON CLEAR INDICATION, T13

This error is logged by the X.25 device driver if timer T13 expired before receipt of a clear confirmation packet.

Refer to Detail Data under X25 ADAPT.

X25 CONFIG

Error Description: X.25 CONFIGURATION ERROR

This error is logged by the X.25 device driver when the adapter fails its internal configuration.

Refer to Detail Data under X25 ADAPT.

X25 IPL

Error Description: ADAPTER ERROR

This error is logged by the X.25 device driver if an adapter timed out during the reboot sequence. This is an installation-related problem and may indicate that the communication equipment was not installed correctly or that the hardware and microcode are incompatible.

Refer to Detail Data under X25 ADAPT.

X25 UCODE

Error Description: X.25 MICROCODE ERROR

This error is logged by the X.25 device driver if the adapter microcode terminates abnormally.

Refer to Detail Data under X25 ADAPT.


[ Previous | Next | Contents | Glossary | Home | Search ]